Product Parameter
| Rated Power (kVA3) | GSI 10/15/20/30 kVA3 | GSI 40/50/60 kVA3 | GSI 80/100/120 kVA3 | GSI 160/200 kVA3 | GSI 250/300 kVA3 |
|---|---|---|---|---|---|
| Rated DC Voltage (VDC) | 220/360/384 | 220/360/384 | 360/384 | 360/384 | 384 |
| Phase | Three phases+N+G | Three phases+N+G | Three phases+N+G | Three phases+N+G | Three phases+N+G |
| Nominal Voltage | 380VAC/400VAC | 380VAC/400VAC | 380VAC/400VAC | 380VAC/400VAC | 380VAC/400VAC |
| Nominal Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Frequency Stability (when out of sync) | <±0.05% | <±0.05% | <±0.05% | <±0.05% | <±0.05% |
| Frequency Stability (when synchronized) | <±5% | <±5% | <±5% | <±5% | <±5% |
| Current Peak Factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| Output Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave |
| THD | Linear load < 3%; Non-linear load < 5% | Linear load < 3%; Non-linear load < 5% | Linear load < 3%; Non-linear load < 5% | Linear load < 3%; Non-linear load < 5% | Linear load < 3%; Non-linear load < 5% |
| Dynamic Load Voltage Transients (from 0 to 100%) | <±5% | <±5% | <±5% | <±5% | <±5% |
| Load Voltage Deviation | <±3% (Balanced Load); <±5% (unbalanced load) | <±3% (Balanced Load); <±5% (unbalanced load) | <±3% (Balanced Load); <±5% (unbalanced load) | <±3% (Balanced Load); <±5% (unbalanced load) | <±3% (Balanced Load); <±5% (unbalanced load) |
| Overload Capacity | 125% 10min, 150% 1min | 125% 10min, 150% 1min | 125% 10min, 150% 1min | 125% 10min, 150% 1min | 125% 10min, 150% 1min |
| Inverter Efficiency (100% load) | >92% | >92% | >92% | >92% | >92% |
| Computer Communication Interface | RS232 (485 Network remote monitoring Optional) | RS232 (485 Network remote monitoring Optional) | RS232 (485 Network remote monitoring Optional) | RS232 (485 Network remote monitoring Optional) | RS232 (485 Network remote monitoring Optional) |
| Operating Temperature | 0~40℃ | 0~40℃ | 0~40℃ | 0~40℃ | 0~40℃ |
| Relative Humidity (No condensation) | 20%~90% | 20%~90% | 20%~90% | 20%~90% | 20%~90% |
| Altitude | ≤5000m (above 1000 meters, rated power derating 1% every 100 meters) | ≤5000m (above 1000 meters, rated power derating 1% every 100 meters) | ≤5000m (above 1000 meters, rated power derating 1% every 100 meters) | ≤5000m (above 1000 meters, rated power derating 1% every 100 meters) | ≤5000m (above 1000 meters, rated power derating 1% every 100 meters) |
| Cooling Method | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling |
| Noise (dB) | 45~65 (1m from the machine) | 45~65 (1m from the machine) | 45~65 (1m from the machine) | 45~65 (1m from the machine) | 45~65 (1m from the machine) |
| Color | Black (Optional) | Black (Optional) | Black (Optional) | Black (Optional) | Black (Optional) |
| Weight (kg) | 190-340 | 450-750 | 750-950 | 1100-1600 | 1800-2300 |
| Dimension (W×D×H mm) | 6006001600 | 8006001600 | 8058001800 | 10059001800 | 110013401920 |